Energy Modeling Guide for Therma-Fuser systems
Description: The Energy Modeling Guide is a quick reference showing step by step how easy it is to energy model a Therma-Fuser system. The guide references the EnergyPro software for examples, but the steps are equally applicable to most other energy modeling software.
Options of Static Pressure Control and Pressure Independence
Description: Provide high enough static pressure to obtain the required air volume and limit the static pressure at both full flow and turndown to avoid diffuser noise.
Comparing Energy Savings of Different VAV Systems - White Paper
Description: White Paper: Comparing Energy Savings of Different VAV Systems
Prepared By: Martyn Dodd
Essentials of a Modular VAV System
Description: The four essential elements of a modular VAV system.
Constant Volume DX Units Including Heat Pumps Sub Zoned with Therma-Fuser Diffusers
Description: How to design a Constant Volume DX or Heat Pump Therma-Fuser diffuser system.
EF Brochure
Description:
EL Brochure
Description: Benefits, how it works, features, performance and system design for the Model EL Therma-Fuser diffuser.
Key Contacts
Description:
Acutherm Contact Sheet
Description:
BACnet: PICS
Description: BACnet Protocol Implementation Conformance Statement
Lon Works: EF XIF File
Description: XIF file for network creation
LonWorks: EF Plugin File
Description: Plugin file for network configuration
LonWorks: Tridium Support Files
Description: Product support files for the Tridium Niagra Framework
P.I.D. (Product Information Description for TLW)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for TL)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for EL)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for ELW)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for AZON-HW)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for AZON-E)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for PIM)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for E-PIM)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for SMC)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for EF)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for STR)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for ST)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for TB)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for TK)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for TN)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for LT)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for VA)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
P.I.D. (Product Information Description for TF)
Description: Use the following model number nomenclature to order Therma-Fuser diffusers, options and accessories.
TN IOM
Description: Installation, balancing, maintenance and operation of the Model TN Therma-Fuser diffuser.
EL IOM
Description: Installation, balancing, maintenance and operation of the Model EL Therma-Fuser diffuser.
EF-L IOM
Description: Installation, balancing, maintenance and operation of the Model EF interoperable with LonWorks.
EF-B IOM
Description: Installation, balancing, maintenance and operation of the Model EF interoperable with BACnet.
List of BACnet Objects
Description: Complete listing of all objects available for the EF-B.
Ordering Nomenclature
Description: Use this document and follow the model number nomenclature to order Therma-Fuser diffusers, options, and accessories.
Damper Position Indicator Option
Description: Damper Position Indicator option for E-PIM DDC Interoperable Pressure Independence Module.
Round Damper
Description: Round Damper for Pressure Independence Module (PIM)
Please contact factory for Options & Accessories on this product.
Description: Acutherm +1 800-544-1840 or +1 510-785-0510
You Tube Video TF
Description:
Wall Adjuster Brochure
Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser.
Digital Remote Wall Adjuster IOM
Description: Installation, operation and maintenance of the Digital Wall Adjuster.
Wireless Remote Wall Adjuster IOM
Description: Installation, operation and maintenance of the Wireless Wall Adjuster.
R-Rings ST, TF, TB
Description: Bypass R-Rings are used to bypass supply air into the ceiling plenum when Therma-Fuser VAV diffusers turn down.
Minimum Flow Stops
Description: Minimum flow options for the Model TF Therma-Fuser diffuser.
KW2013
Description:
Minimum Security Lattice
Description: For minimum security areas of correctional facilities, prisons, psychiatric hospitals and manufacturing plants.
TF-HC No Heat
Description: A VAV diffuser that stays closed when the supply air is warm.
TF-HC Limited Heat
Description: A VAV diffuser where the maximum air volume in heating may be adjusted from 0-100% of capacity.
2 x 2 Ceiling Approaches
Description: Adaptor frames and options for other than lay in ceilings.
Guide Specification for ELW
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for EL
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for EF
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for AZON-II-W
Description: Guide specification suitable for the CSI Master Format.
Guide Specification for AZON-I-E and AZON-II-E
Description: Guide specification suitable for the CSI Master Format.
Guide Specification for System Mode Control Module (SMC)
Description: Guide specification suitable for CSI Master Format.
Guide Specification for Pressure Independence Module (PIM)
Description: Suitable for the CSI Master Format.
Guide Specification for TLW-CW, TLW-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TL-CW, TL-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TN-CW, TN-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for Interoperable Pressure Independence Module (EPIM)
Description: Suitable for the CSI Master Format.
Guide Specification for TK-HC, TK-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for STR-HC, STR-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TB-CW, TB-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for ST-HC, ST-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for LT-HC
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for LT-CW, LT-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TF-HC
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for VA-HC
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TF-CW, TF-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TF-HC-NH
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for TF-HC-LH
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
Guide Specification for VA-CW, VA-C
Description: Guide specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI Master Format.
.
Description: Acutherm - 1766 Sabre Street - Hayward CA 94545 - USA
AZON-I-E Submittal
Description: Submittal for AcuZone1 Electric Heater
AZON-II-E Submittal
Description: Submittal for the AcuZone2 Electric Zone Heater
How It Works (ST-HC model)
Description: See how a Therma-Fuser VAV diffuser works. (ST-HC MODEL)
Therma-Fuser Diffusers are ceiling diffusers with built in room thermostats allowing individuals to select their comfort setting (temperature).
How It Works (TF-HC model)
Description: See how a Therma-Fuser VAV Diffuser works. (TF-HC model)
Therma-Fuser Diffusers are ceiling diffusers with built in room thermostats allowing individuals to select their comfort setting (temperature).
Benefits Video
Description: This short video will walk you through the 5 basic benefits of the Therma-Fuser VAV System: Comfort, Quality, Superior Technology, Energy Efficient, and Cost Effective.
Easily Adapts - YouTube
Description: SUSTAINABLE DESIGN:
SEE HOW A THERMA-FUSER SYSTEM EASILY ADAPTS TO OFFICE LAYOUT CHANGES.
No Therma-Fuser zone is split when office walls are put up or moved, contributing significantly to the long-term sustainability of a building
Individual Comfort - Look Up
Description: Look up into the windows of a busy office building and you'll see that HVAC needs are constantly changing throughout the day.
Recommendations for Low Energy VAV Systems
Description: Energy tips. Recommendations for low energy VAV systems. This document is a portion of the White Paper “Comparing Energy Savings of Different VAV Systems”.
TF BIM Models
Description: 3D CAD models suitable for Revit® - Includes all sizes of TF-HC, TF-CW, TF-C, and TF-D.
TF BIM Face Based Models
Description: 3D CAD models suitable for Revit® - Includes all sizes of TF-HC, TF-CW, TF-C, and TF-D.
TF-RA BIM Models
Description: 3D CAD models suitable for Revit® - Includes all sizes of TF-RA.
TF-RA BIM Face Based Models
Description: 3D CAD models suitable for Revit® - Includes all sizes of TF-RA.
Lowest Energy VAV Terminal
Description: Independent studies confirm that Therma-Fuser Diffusers are the lowest environmental impact - green - VAV terminals.
Easily Adapts to Office Layout Changes
Description: Therma-Fuser diffusers are more adaptable to office change with no zones being split when office walls are moved.
Lowest Cost Per Zone
Description: Therma-Fuser diffusers provide the lowest installed cost per zone of control.
Superior Air Distribution - YouTube
Description: WATCH LAB DEMOS OF SUPERIOR AIR DISTRIBUTION WITH THERMA-FUSER DIFFUSERS.
The variable air opening within all Therma-Fuser diffuser models creates high air velocity, even at lower supply volumes. This maintains the Coanda effect where high velocity air hugs an adjacent surface, holding cold air up to the ceiling and prevents dumping.
Superior Air Distribution
Description: Therma-Fuser diffusers provide better throw, higher room air movement and uniform temperature distribution.
Low Energy VAV Systems Using VAV Packaged DX Rooftop Units
Description: How-To Design Low Energy VAV Systems Using VAV Packaged DX Rooftop Units
Controlling Duct Heat Sub Zoned with Therma-Fuser Diffusers
Description: How to design a Duct Heat Therma-Fuser diffuser system.
Air Handling and Fan Coil Units Sub Zoned with Therma-Fuser Diffusers
Description: How to design an Air Handling or Fan Coil Unit Therma-Fuser diffuser system.
Dual Duct Boxes Sub Zoned with Therma-Fuser Diffusers
Description: How to design a Dual Duct (Double Duct) Box Therma-Fuser diffuser system.
VAV Boxes Sub Zoned with Therma-Fuser Diffusers
Description: How to design a VAV Box Therma-Fuser diffuser system.
VAV Reheat Boxes Sub Zoned with Therma-Fuser Diffusers
Description: How to design a VAV Reheat Box Therma-Fuser diffuser system.
Continuous Fan Powered Boxes Sub Zoned with Therma-Fuser Diffusers
Description: How to design a Continuous Fan Powered Box Therma-Fuser diffuser system.